YH7008 Similiar FLUKE 715 Volt/mA Calibrators

YH7008 Similiar FLUKE 715 Volt/mA Calibrators
Product Detailed
YH7008 Volt/mA Calibrators 0.025% accuracy Loop Calibrator 4-20mA loop Calibrators Voltages and Current Loop Source and curre

YH7008 Similiar FLUKE 715 Volt/mA Calibrators 

YH7008 Volt/mA Calibrators0.025% accuracy Loop Calibrator4-20mA loop CalibratorsVoltages and Current Loop Source and current

We can provide OEM Service for customers completely

Features

The fast, one-handed tool for loop checks. Just click to calibrate.

This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:

Large display and simple, quick-click interface for easy one-handed operation.Simultaneous mA and % readout for quick, easy interpretation of readings.mA accuracy of 0.025%, superior to other loop calibrators in this price range.1 µA resolution for mA source, simulate and measure.Push button 25% steps for fast, easy linearity checks.0-100% “span check” for fast confirmation of zero and span.Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests. 24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.

New R&D Features by Yehai

Measures o-10v DC&0-100mV DC with accuracy 0.02%Output  o-10v DC&0-100mV DC with accuracy 0.02%0 - 20 mA or 4 - 20 mA output range could be set manuallyrechargabel lithiumion battery pack.Push button 25% steps or fast,easy linerity checksSpecifications

Current Measurement

Range:

0 to 24 mA

Resolution:

0.001 mA

Accuracy:

0.02%+4dgt

Current Sourcing

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.02%+4dgt

Drive Capability:

To 1000 Ω at 20mA

Current Simulation

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.02%+4dgt

Ext. loop voltage requirement:

12-30 V

Loop Power

While measuring mA, 24 V

Voltage measurement

Range:

0 to 10 V DC

Resolution:

1 mV

Accuracy:

0.02% +4Rdg

mV DC MeasureRange0 to10v DC
 Resolution1mV
 Accuracy 0.02% +4Rdg
V DC OuputRange0 to 100mV
 Resolution0.01mV
 Accuracy 0.02% +4Rdg
mV DC OuputRange0 to 100mV
 Resolution0.01mV
 Accuracy 0.02% +4Rdg
Environmental Specifications

Operating Temperature -10ºC to 55ºC

Storage Temperature -40ºC to 60ºC

Humidity (Without Condensation) 0 to 90% (0ºC to 35ºC); 0 to 70% (35ºC to 55ºC)

Temperature Coefficient -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC

Safety Specifications

Maximum voltage 30V

Mechanical & General Specifications

Size 152 x 70 x 41 mm

Weight 224 g (340 g including holster)

Batteries One 9V battery Alkaline(YHS-707) , One 9V battery

Warranty Two years

Shock & Vibration per MIL-T-28800 for a Class 2 Instrument

Display current and % of span Yes

Auto step, auto ramp Yes

Span Check Yes

Accessories Included

Item DescriptionQuantity
1A 7.4v Li-polymer battery1
2

Test Lead red

Test Lead black

1

1

3

Bending test plug wire clip (red)

Bending test plug wire clip(black)

1

1

4Adapeter(DC 10V 1A)1
5Instruction Sheet1
6Certification1
Specifications of Loop Calibrator FOR YHS717 Loop Calibrators(YHS718 Volt/mA Calibrators is the update for YHS717 Loop Calibrators)

Current Measurement

Range:

0 to 24 mA

Resolution:

0.001 mA

Accuracy:

0.025% Rdg + 2 LSD

Current Sourcing

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.025% Rdg + 2 LSD

Drive Capability:

1200 Ω; 950 Ω at 20 mA in HART mode

Current Simulation

Range:

0 to 20 mA or 4 to 20 mA

Accuracy:

0.025% Rdg + 2 LSD

Ext. loop voltage requirement:

12-30 V

Loop Power

While measuring mA, 24 V

Voltage measurement

Range:

0 to 28 V DC

Resolution:

1 mV

Accuracy:

0.025% Rdg + 2 LSD

YHS-707 Loop Calibrator Similiar to Fluke707 mA Calibrator
 

YHS-717

Fluke 707

DC Volts Input

0~28.000V ± (0.025% + 4digit)

0~28V  ± (0.025% + 1dgt)

DC mA Input

0~24.000mA ± (0.025% + 4dgt)

0~24.000mA ± (0.02% + 4dgt)

DC mA Output

Source output mA or Simulate output mA

Loop power output mA

0~20.000mA or 4~20mA

± (0.025% + 2dgt)

Source output mA or Simulate output mA

Loop power output mA

0~20.000mA or 4~20mA

± (0.015% + 2dgt)

Loop Power

24V

24V

Percent display

250 Ω HART resistance

Signal Adjust mode

Special (quick induction)

Special (quick induction)

Auto ramp (smooth/step)

Back Light

Barrery

Lithium Battery (7.4V) YHS717

NON-rechargeable battery

One 9 Valkaline

  

USD 897/pcs

Attn:Rene Chow

TM:cn1001604516

QQ:862457367

Phone:0086-136-3169-7416

YH7008 Similiar FLUKE 715 Volt/mA Calibrators



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.